Learning objectives
- Quantify how a different close convention moves a frozen pivot map.
- Reconcile two feeds before comparing their trading signals.
Prerequisites: Calculate floor pivots and distinguish a last trade from a settlement reference.
Mechanism and interpretation
Two correct pivot calculators can disagree because they summarize different sessions or use different close definitions. Hold high and low fixed to isolate the close effect. If the close changes byΔC, the central pivot changes byΔC/3. First support and resistance, which contain 2P, change by 2ΔC/3. Second support and resistance change byΔC/3 because the high-low range is unchanged.
This sensitivity calculation is a diagnostic. It tells you whether a discrepancy has the fingerprint of a close substitution. A session-boundary change can also alter high and low, so the simple relationship no longer isolates the whole difference. Record feed, timezone, session, close convention and data revision before deciding that one platform is wrong. Agreement on the name daily is not enough.
Worked case · synthetic data
Synthetic H=120, L=100, last trade close 118 and settlement close 115. Last-tradeP=112.6667; settlementP=111.6667, a decline of 1. The correspondingR 1 values are 125.3333 and 123.3333, a decline of 2. The close fell 3, matchingΔP=−3/3 andΔR1=2×(−3)/3. This arithmetic explains the difference without assuming any market error.
Failure modes and context
Settlement methods and publication timing are instrument-specific. A final settlement value may arrive after a strategy's actual decision time. A feed corrected later can improve a historical chart while creating unavailable information in a backtest. Do not switch conventions session by session to obtain the most favorable level; freeze the rule and retain source versions.
Practice assignment
Keep H=90, L=70 fixed. Compare closes 88 and 82. Compute bothP andR 1 values and their changes. Then explain what extra checks are required if the two feeds also disagree about the high.
Worked answer
The pivots are 82.6667 and 80.6667, soΔP=−2. R1 values are 95.3333 and 91.3333, soΔR1=−4. If the high differs, check session inclusion, corrections and instrument mapping; close sensitivity alone cannot explain all level changes.
Check your understanding
Question 1
A close-only change of−6 movesP by how much?
- −6
- −12
- −2
Reveal answer and reasoning
C. −2
P contains one third of the close, so divide the change by 3.
Question 2
Why canR 1 move twice as much asP?
- R1 always equals the high
- R1 contains 2P while low is fixed
- R1 uses no close
Reveal answer and reasoning
B. R1 contains 2P while low is fixed
The algebraR 1=2P−L doubles the pivot change.
Question 3
Does a final revised settlement necessarily exist at the original decision time?
- No
- Yes
- Only on daily charts
Reveal answer and reasoning
A. No
Availability and revision timestamps must match the historical decision.